Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter
1 Piece
MOQ
large.img.alt
Features Gallery Product Description Request A Quote
Features
Basic Infomation
Place of Origin: China
Brand Name: ACMESENSOR
Certification: CE
Model Number: AUF803
High Light:

Clamp Pipe Type Ultrasonic Water Flow Meter

,

Ultrasonic Water Flow Meter DIN6000MM

,

Fixed Mounted ultrasonic pipe flow meter

Payment & Shipping Terms
Packaging Details: Standard export package for Ultrasonic level sensor for liquid underwater detector oil and water
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000 Piece/Pieces per Month
Specifications
Pipe Size:: DN15-6000MM
Flow Range:: 0~±10m/s
Accuracy:: ±1%
Output:: 4-20mA, OCT Pulse, Relay Output
Mounting Type:: Clamp On Type, Plug In Type, Pipe Type
Power Supply:: DC8-36V;AC85-264V(optional)
Medium:: Water, Seawater, Sewage,plant Effluent Etc.
Working Temp:: -30℃~+160℃
Product Description

AUF803 fixed mounted clamp pipe type Ultrasonic flow meter

Product Description

 

Ultrasonic Flow Meter is the new product is designed strictly according to JJG1030-2007 standard to develop the reliability of protect class. Ultrasound transmit time principle makes the measurement range from DN15 to DN6000.

The advantages include high accuracy, strong anti-interference, reliability and stability, multiple interface. Each parts can achieve to IP68,enable the meter work in any severe environment.

Feature

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 0

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 1

Detail show IP68 ultrasonic flow meter

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 2

ntegrated Ultrasonic flowmeter consists of (π type + Standard flange type)

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 3

π type inline ultrasonic flow meter(DN15mm-DN32mm)

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 4

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 5

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 6

Standard inline ultrasonic flow meter(DN40mm-DN1000mm)

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 7

Specification IP68 ultrasonic flow meter

 

Item Principle and parameters
Converter Principle Transit-time,4 byte floating-point operation in accordance with IEEE754
Accuracy

Inline type:flow meter:±0.5%; heat meter:±1.0%

Clamp on type:flow meter:±1.0%; heat meter:±2.0%

Insertion type:flow meter:±1.0%; heat meter:±2.0%

 

Operation

4-key manipulation with magnetic bar touch or figer touch;

simulation keyboard software

Output

One way 4-20mA analog output

One way OCT pulse signal output

One way Relay output

Input

3 way 4-20mA analog input,accuracy:0.1%;

Acquisition signal of temperature,press and liquid level

Achieve heat measurement by connecting 3-wired PT100

Temperature sensor

Data interface RS485 serial interface,upgraded by computer,support MODBUS communication protocol
Special cable Twisted-pair shielded cable and cable length should be no more than 50 m.Transmission distance can achieve 1 km if select the RS 485 interface
pipeline Pipe material Steel,stainless,copper,cement,PVC,aluminum,glass steel, cast iron
Pipe diameter DN15mm-DN6000mm
Straight pipeline

Transducers installation points should be:10 diameters’ straight pipeline from upstream transducer ,5 diameters’

straight pipeline from the downstream transducer ;30 diameters’ straight pipeline from the pump

Measuring

Medium

 

Liquid type

Single liquid that can conduct sound wave,such as water,

Seawater, sewage,plant effluent,chemicals,alcohol,beer,oil

etc.

Fluid temperature -30℃-160
Turbidity 10000ppm,with little bubble
Fluid velocity 0m/s-7m/s

Working

Environment

Temperature Converter:-20℃-60℃;transducer:-30-160
Humidity Both of the converter and transducers can work under water,depth underwater ≤2m(After completely sealing)
Power supply DC8-36V;AC85-264V(optional)
Power consumption 1.5W

Sensor options

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 8

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 9

 

Clamp Pipe Type Ultrasonic Water Flow Meter Fixed Mounted Ultrasonic Pipe Flow Meter 10

FAQ

Q:Can you accept ODM & OEM service ?
A:We professional provide OEM &ODM service for all of items.
Q:Could I get samples?
A:Yes,we have materials in stock to help you to get the samples as soon as we can.
Q:How about the quality of the magnets?
A:We have the certification of ISO,CE and ROSH,we could send the certification test of our company to you.
Q:How is the price?
A:As we believe the quality is the most important,we will provide the best quality ultrasonic level sensor we can with reasonable
price.
Q:Could you provide me the shortest lead time?
A:We have materials in our stock,if you really need,you can tell us and we will try our best to satisfy you.
Q: How can I get my sensors?/ What's the means of transport?
A. We main delivery goods by express: DHL, FedEx, UPS,TNT, etc or logistics by indicator
Q. How to order ?
A. In order to recommend you the most suitable radar level sensors and make an accurate quotation, please provide the following information and send it to our sales when you are going to make an inquiry, thanks !
1. What is your medium? Water, oil or others?
2. Level range: 0-10meters, or others?
3. Output signal: 4-20mA, RS485 or others?

 

Recommended Products
Get in touch with us
Tel : +86-15902942317
Fax : 86--15902942317
Characters Remaining(20/3000)